7.2 Executing a Test Switch Using BCS
Commands
The following test switch routes Input 1 to Output 2 on Level 0. Before
executing these switches, make sure the first two inputs and outputs are
connected exactly as shown in the AutoPatch “Modula Connector and
Groupings Guide.”
To execute a test switch, enter the following BCS command line into a
serial terminal program attached to the matrix:
CL0I1O2T
For a complete list of BCS commands, see Appendix C in the back of
this guide.
If the switch did not execute properly:
q
Check all power switches to make sure the source and destination
devices are turned on.
q
Check all link and signal connections on the rear of the enclosure(s)
to make sure everything is physically set up properly.
q
Attempt the switch again.
If the switch still does not work, call AutoAssist (see Technical Support,
page v).
7-4 Installation and Setup Guide
Executing a Test Switch
Test Switch